{"id":168911,"date":"2024-05-29T17:37:30","date_gmt":"2024-05-29T08:37:30","guid":{"rendered":"https:\/\/www.nopgroup.com\/?post_type=product&#038;p=168911"},"modified":"2024-12-02T16:06:41","modified_gmt":"2024-12-02T07:06:41","slug":"2my-2hw-wfilter","status":"publish","type":"product","link":"https:\/\/www.nopgroup.com\/en\/product\/2my-2hw-wfilter\/","title":{"rendered":"2MY with double filters (2HW)"},"content":{"rendered":"\n<figure class=\"wp-block-flexible-table-block-table tro-ta\"><table class=\"has-fixed-layout\"><tbody><tr><th>Applications<\/th><td>Transport of coolant fluid ( water soluble type\/ oil type)<\/td><td><a href=\"https:\/\/www.nopgroup.com\/wp\/wp-content\/uploads\/2024\/05\/22478a12b9f483daea74fea8d9a91361.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Fluid compatibility table<\/a><\/td><\/tr><tr><th>Permissible fluid temperature<\/th><td>-5\uff5e80\u2103 (23\u00b0F~176\u00b0F)<\/td><td><\/td><\/tr><tr><th>Permissible viscosity<\/th><td>2\uff5e50mm<sup>2<\/sup>\/sec (HWM type)<\/td><td><\/td><\/tr><tr><th>Relief valve<\/th><td>With external relief valve (VD type)<\/td><td><a href=\"https:\/\/www.nopgroup.com\/wp\/wp-content\/uploads\/2024\/05\/12c22eb60c53665b03e2b73ffa1feddc.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">More details<\/a><\/td><\/tr><tr><th>Filter type<\/th><td>Washable element type<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Specification<\/h2>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table is-scroll-on-mobile\"><table class=\"has-fixed-layout is-sticky-first-column\" style=\"width:100%;max-width:100%\"><tbody><tr><th class=\"fixed\" rowspan=\"3\">Model<\/th><th rowspan=\"3\">Theoretical<br>discharge \u2113\/min (US gal\/min)<\/th><th colspan=\"4\">Motor rotation speed<br>50Hz\/1500min<sup>-1<\/sup><\/th><th rowspan=\"3\">Theoretical<br>discharge \u2113\/min (US gal\/min)<\/th><th colspan=\"4\">Motor rotation speed <br>60Hz\/1800min<sup>-1<\/sup><\/th><\/tr><tr><th colspan=\"4\">Max. discharge pressure MPa (psi)<\/th><th colspan=\"4\">Max. discharge pressure MPa (psi)<\/th><\/tr><tr><th>200W<\/th><th>400W<\/th><th>750W<\/th><th>1500W<\/th><th>200W<\/th><th>400W<\/th><th>750W<\/th><th>1500W<\/th><\/tr><tr><th class=\"fixed\">TOP-204HWMDPVDE<\/th><td>6 (1.59)<\/td><td>1.2 (174.05)<\/td><td>2 (290.08)<\/td><td>2 (290.08)<\/td><td>2 (290.08)<\/td><td>7.2 (1.9)<\/td><td>1 (145.04)<\/td><td>2 (290.08)<\/td><td>2 (290.08)<\/td><td>2 (290.08)<\/td><\/tr><tr><th class=\"fixed\">TOP-206HWMDPVDE<\/th><td>9 (2.38)<\/td><td>0.8 (116.03)<\/td><td>1.8 (261.07)<\/td><td>2 (290.08)<\/td><td>2 (290.08)<\/td><td>10.8 (2.85)<\/td><td>0.6 ( 87.02)<\/td><td>1.6 (232.06)<\/td><td>2 (290.08)<\/td><td>2 (290.08)<\/td><\/tr><tr><th class=\"fixed\">TOP-208HWMDPVDE<\/th><td>12 ( 3.17)<\/td><td>0.6 ( 87.02)<\/td><td>1.4 (203.05)<\/td><td>2 (290.08)<\/td><td>2 (290.08)<\/td><td>14.4 (3.8)<\/td><td>0.4 (58.02 )<\/td><td>1.2 ( 174.05)<\/td><td>2 (290.08)<\/td><td>2 (290.08)<\/td><\/tr><tr><th class=\"fixed\">TOP-210HWMDPVDE<\/th><td>15 ( 3.96)<\/td><td>0.4 (58.02 )<\/td><td>1.2 (174.05)<\/td><td>2 (290.08)<\/td><td>2 (290.08)<\/td><td>18 (4.76)<\/td><td>0.3 ( 43.51)<\/td><td>1 ( 145.04)<\/td><td>1.9 (275.57)<\/td><td>2 (290.08)<\/td><\/tr><tr><th class=\"fixed\">TOP-212HWMDPVDE<\/th><td>18 (4.76)<\/td><td>0.3 (43.51)<\/td><td>1 (145.04)<\/td><td>2 (290.08)<\/td><td>2 (290.08)<\/td><td>21.6 (5.72)<\/td><td>&#8211;<\/td><td>0.8 (116.03)<\/td><td>1.6 (232.06)<\/td><td>2 (290.08)<\/td><\/tr><tr><td colspan=\"5\"><a href=\"https:\/\/www.nopgroup.com\/wp\/wp-content\/uploads\/2024\/05\/trochoid_pump_products_guide_en-048-2MY-W-Filter-.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><\/a><a href=\"https:\/\/www.nopgroup.com\/wp\/wp-content\/uploads\/2024\/05\/trochoid_pump_products_guide_en-048-2MY-W-Filter-.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Model numbering system<\/a><\/td><td colspan=\"6\"><a href=\"https:\/\/www.nopgroup.com\/wp\/wp-content\/uploads\/2024\/05\/8e37108c1d682b2511d38d3d22beaaca.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><\/a><a href=\"https:\/\/www.nopgroup.com\/wp\/wp-content\/uploads\/2024\/05\/8e37108c1d682b2511d38d3d22beaaca.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Performance curve<\/a><\/td><\/tr><\/tbody><\/table><figcaption>\u25cbCondition of Maximum discharge pressure: measured at ISO-VG2 oil at 40\u2103(104\u00b0F).<br>\u25cbVisocisty range of pumped liquid is10\uff5e50mm<sup>2<\/sup>\/sec. he vacuum gauge indicate beyond the green zone if pumped fluid exceeds the permissible viscosity range.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"featured_media":3354,"parent":0,"template":"","all_category":[248],"class_list":["post-168911","product","type-product","status-publish","has-post-thumbnail","hentry","all_category--2hw","en-US"],"_links":{"self":[{"href":"https:\/\/www.nopgroup.com\/wp-json\/wp\/v2\/product\/168911","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.nopgroup.com\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.nopgroup.com\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":60,"href":"https:\/\/www.nopgroup.com\/wp-json\/wp\/v2\/product\/168911\/revisions"}],"predecessor-version":[{"id":177745,"href":"https:\/\/www.nopgroup.com\/wp-json\/wp\/v2\/product\/168911\/revisions\/177745"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.nopgroup.com\/wp-json\/wp\/v2\/media\/3354"}],"wp:attachment":[{"href":"https:\/\/www.nopgroup.com\/wp-json\/wp\/v2\/media?parent=168911"}],"wp:term":[{"taxonomy":"all_category","embeddable":true,"href":"https:\/\/www.nopgroup.com\/wp-json\/wp\/v2\/all_category?post=168911"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}